Depends on local codes.
Aav vent in attic.
More product details.
The attic has certain conditions that can affect the aav performance which should be considered before choosing this as a location.
I have read that it s allowed in some cases.
Automatic air vents are no longer approved and should be replaced.
The temperature ranges that the sure vent will operate in are 40 f to 150 f your attic can experience drastic temperature variations depending on how it is vented and your geographic location.
These valves are gravity operated devices that respond to the negative pressure of draining water and open to let air in.
The oatey sure vent 1 1 2 in.
Aavs in attics should be at least six inches above the attic insulation.
A plumber would probably know the answer to the vent issue but would he know or.
The temperature ranges that the sure vent will operate in are 40 f to 150 f your attic can experience drastic temperature variations depending on how it is vented and your geographic location.
The irc allows them on a waste stack that terminates in an attic as long as the aav is 6 inches above the insulation.
Depending on the valve and the size of the vent aavs can support one or multiple vent lines.
The attic has certain conditions that can affect the aav performance which should be considered before choosing this as a location.
Call a licensed plumber to fix the problem.
X 2 pvc air admittance valve features a 1 way valve that permits air to enter when negative pressures develop in the piping system.
Prevents sewer gases from escaping into a building.
This vent is for a master bath addition 3 drain vent.
One solution is an air admittance valve or aav.
When an aav is installed in an attic make sure that it s at least 6 inches above insulation any less and there s a good chance insulation will be drawn into the unit severely affecting performance.
Aav vent terminates in attic.
Then gravity closes the valve keeping sewer gases out of the room.
X 2 the oatey sure vent 1 1 2 in.
Aavs must be accessible.
The relief vent must connect to the vent stack stack vent or extend outdoors to the open air unless it is used in conjunction with a stack that is connected to a p a p a.
This application may have been approved by this local jurisdiction however you should be aware that this type of system is not recognized by california building officials as an approved vent system.
To ensure proper operation of your aav make sure that the surrounding area is free of obstructions and things that can knock against it.
Device and aavs on the branches.
Only teflon tape can be used on the valves threads.
Aav s have to be readily accessible not sure if the ahj will consider them accessible while in the attic.
The relief vent may also serve as a vent for the fixture.
Closes by gravity to seal the vent terminal at zero differential pressure.
Seriously though i can t think of any application where in a dw vent may be terminated in an attic space.